Energy conservation and emission reduction and environmental protection are no longer slogans, and safety production is closely related to every enterprise and every citizen. As is well known, in industries such as pharmaceuticals and chemicals, there are quite a few production processes that use organic solvents such as methanol, ethanol, acetone, and toluene as solvents. When entering the drying unit, recycling these solvents as much as possible can not only reduce production costs and improve enterprise economic benefits, but also reduce environmental pollution and benefit oneself and the people. Meanwhile, due to the flammability and explosiveness of such organic solvent gases, explosion-proof measures must be taken at the production site to ensure the safety of life and property. Our company's technology personnel fully utilize our years of professional experience in producing drying equipment and the technical advantages of being familiar with automatic control in chemical production. We closely cooperate with users, carefully design and repeatedly improve, and have produced the exquisite BXFG series closed-loop circulating boiling dryer.
Specification and model Technical Parameter | XF0.25-1 | XF0.25-2 | XF0.25-3 | XF0.25-6 | XF0.3-2 | XF0.3-4 | XF0.3-6 | XF0.3-8 | XF0.3-10 | XF0.4-4 | XF0.4-6 |
Bed area(m²) | 0.25 | 0.5 | 1.0 | 1.5 | 0.6 | 1.2 | 1.8 | 2.4 | 3.0 | 1.6 | 2.4 |
Drying capacity(kg H₂O/h) | 10~15 | 20~25 | 30~45 | 52~75 | ~30 | 42~60 | 63~90 | 84~120 | 105~150 | 56~80 | 84~120 |
Fan power(kw) | 5.5 | 7.5 | 15 | 22 | 7.5 | 18.5 | 30 | 37 | 48 | 30 | 37 |
Inlet air temperature(oC) | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 |
Material temperature(oC) | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 |
External dimensions (host) length x width x height (m) | 1×0.6×3.35 | 2×0.6×3.35 | 4×0.6×3.35 | 6×0.6×3.35 | 2×0.7×3.4 | 4×0.7×3.4 | 6×0.7×3.4 | 8×0.7×3.4 | 10×0.7×3.4 | 4×1×3.58 | 6×1×3.58 |
Cover an area(m²) | 18 | 25 | 35 | 40 | 25 | 38 | 45 | 56 | 70 | 18 | 56 |
Specification and model Technical Parameter | XF0.4-8 | XF0.4-10 | XF0.4-12 | XF0.5-4 | XF0.5-6 | XF0.5-8 | XF0.5-10 | XF0.5-12 | XF0.5-14 | XF0.5-16 | XF0.5-18 |
Bed area(m²) | 3.2 | 4.0 | 4.8 | 2.0 | 3.0 | 4.0 | 5.0 | 6.0 | 7.0 | 8.0 | 9.0 |
Drying capacity(kg H₂O/h) | 112~160 | 140~200 | 168~240 | 70~100 | 105~150 | 140~200 | 175~250 | 210~300 | 245~350 | 280~400 | 315~450 |
Fan power(kw) | 48 | 70 | 70 | 30 | 48 | 70 | 105 | 140 | 147 | 169 | 197 |
Inlet air temperature(oC) | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 | 120~140 |
Material temperature(oC) | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 | 40~60 |
External dimensions (host) | 8×1×3.58 | 10×1×3.58 | 12×1×3.58 | 4×1.2×4.1 | 6×1.2×4.1 | 8×1.2×4.1 | 10×1.2×4.1 | 12×1.2×4.1 | 14×1.2×4.1 | 16×1.2×4.1 | 18×1.2×4.1 |
Cover an area(m²) | 74 | 82 | 96 | 50 | 70 | 82 | 100 | 140 | 180 | 225 | 268 |
Note:
1、 The feeding methods include: A. Star shaped feeding. B. Use both star shaped feeding and pneumatic conveying. C. Belt conveyor. D. User defined.
2、 Can achieve automated production. 3、 In addition to the above models, special designs can be made for users. 4、 The power of the fan varies depending on the material used.